The Journal of General Physiology
Cell MicroControls
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

Published 31 March 2003. doi:10.1085/jgp.200208777
This Article
Right arrow Full Text
Right arrow Full Text (PDF, 1589K)
Right arrow PPT slides of all figures
Right arrow Alert me when this article is cited
Right arrow Citation Map
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JGP
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kang, T. M.
Right arrow Articles by Hilgemann, D. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kang, T. M.
Right arrow Articles by Hilgemann, D. W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
© Rockefeller University Press, 0022-1295/2003/4/325/ $5.00
Journal of General Physiology, Volume 121, Number 4, April 2003 325-348

Ion Fluxes in Giant Excised Cardiac Membrane Patches Detected and Quantified with Ion-selective Microelectrodes

Tong Mook Kang1, Vladislav S. Markin2 and Donald W. Hilgemann1

1 Departments of Physiology, The University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390
2 Anaesthesiology and Pain Management, The University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390

Address correspondence to Donald W. Hilgemann, Department of Physiology University of Texas Southwestern Medical Center at Dallas, 5323 Harry Hines Boulevard Dallas, TX 75390-9040. Fax: (214) 648-8879; E-mail: donald.hilgemann{at}utsouthwestern.edu

We have used ion-selective electrodes (ISEs) to quantify ion fluxes across giant membrane patches by measuring and simulating ion gradients on both membrane sides. Experimental conditions are selected with low concentrations of the ions detected on the membrane side being monitored. For detection from the cytoplasmic (bath) side, the patch pipette is oscillated laterally in front of an ISE. For detection on the extracellular (pipette) side, ISEs are fabricated from flexible quartz capillary tubing (tip diameters, 2–3 microns), and an ISE is positioned carefully within the patch pipette with the tip at a controlled distance from the mouth of the patch pipette. Transport activity is then manipulated by solution changes on the cytoplasmic side. Ion fluxes can be quantified by simulating the ion gradients with appropriate diffusion models. For extracellular (intrapatch pipette) recordings, ion diffusion coefficients can be determined from the time courses of concentration changes. The sensitivity and utility of the methods are demonstrated with cardiac membrane patches by measuring (a) potassium fluxes via ion channels, valinomycin, and Na/K pumps; (b) calcium fluxes mediated by Na/Ca exchangers; (c) sodium fluxes mediated by gramicidin and Na/K pumps; and (d) proton fluxes mediated by an unknown electrogenic mechanism. The potassium flux-to-current ratio for the Na/K pump is approximately twice that determined for potassium channels and valinomycin, as expected for a 3Na/2K pump stoichiometery (i.e., 2K/charge moved). For valinomycin-mediated potassium currents and gramicidin-mediated sodium currents, the ion fluxes calculated from diffusion models are typically 10–15% smaller than expected from the membrane currents. As presently implemented, the ISE methods allow reliable detection of calcium and proton fluxes equivalent to monovalent cation currents <1 pA in magnitude, and they allow detection of sodium and potassium fluxes equivalent to <5 pA currents. The capability to monitor ion fluxes, independent of membrane currents, should facilitate studies of both electrogenic and electroneutral ion–coupled transporters in giant patches.

Key Words: ion-selective electrodes • patch clamp • Na/K pump • Na/Ca exchange • proton transport


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Physiol. Cell Physiol.Home page
M. G. Blanchard, J.-P. Longpre, B. Wallendorff, and J.-Y. Lapointe
Measuring ion transport activities in Xenopus oocytes using the ion-trap technique
Am J Physiol Cell Physiol, November 1, 2008; 295(5): C1464 - C1472.
[Abstract] [Full Text] [PDF]


Home page
JGPHome page
D. Fuster, O. W. Moe, and D. W. Hilgemann
Steady-state Function of the Ubiquitous Mammalian Na/H Exchanger (NHE1) in Relation to Dimer Coupling Models with 2Na/2H Stoichiometry
J. Gen. Physiol., October 1, 2008; 132(4): 465 - 480.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
G. Zifarelli, P. Soliani, and M. Pusch
Buffered Diffusion around a Spherical Proton Pumping Cell: A Theoretical Analysis
Biophys. J., January 1, 2008; 94(1): 53 - 62.
[Abstract] [Full Text] [PDF]


Home page
J Exp BotHome page
R. R. Lew
Ionic currents and ion fluxes in Neurospora crassa hyphae
J. Exp. Bot., September 26, 2007; (2007) erm204v1.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
D. Fuster, O. W. Moe, and D. W. Hilgemann
Lipid- and mechanosensitivities of sodium/hydrogen exchangers analyzed by electrical methods
PNAS, July 13, 2004; 101(28): 10482 - 10487.
[Abstract] [Full Text] [PDF]


Home page
JGPHome page
P. Artigas and D. C. Gadsby
Large Diameter of Palytoxin-induced Na/K Pump Channels and Modulation of Palytoxin Interaction by Na/K Pump Ligands
J. Gen. Physiol., March 29, 2004; 123(4): 357 - 376.
[Abstract] [Full Text] [PDF]



  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents