The Journal of General Physiology
89 NORTH - Illumination Systems for Fluorescence Imaging
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF, 1169K)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JGP
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stienen, G. J.
Right arrow Articles by Blange, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stienen, G. J.
Right arrow Articles by Blange, T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

The Journal of General Physiology, Vol 78, 151-170, Copyright © 1981 by The Rockefeller University Press


ARTICLES

Local movement in stimulated frog sartorius muscle

GJ Stienen and T Blange

Local movement was recorded in tetanically contracting frog sartorius muscle to estimate the nonuniformity in the distribution of compliance in the muscle preparation and the compliance that resides in the attachments of the preparation to the measuring apparatus. The stimulated muscle was also subjected to rapid length changes, and the local movements and tension responses were recorded. The results indicate that during tension development at resting length the central region of the muscle shortens at the expense of the ends. After stimulation the "shoulder" in the tension, which divided the relaxation into a slow decline and a subsequent, rather exponential decay toward zero, was accompanied by an abrupt increase in local movement. We also examined the temperature sensitivity of the two phases of relaxation. The results are consistent with the view that the decrease in tension during relaxation depends on mechanical conditions. The local movement brought about by the imposed length changes indicates that the peak value of the relative length change of the uniformly acting part was approximately 20% less than the relative length change of the whole preparation. From these observations, corrections were obtained for the compliance data derived from the tension responses. These corrections allow a comparison with data in the literature obtained from single fiber preparations. The implications for the stiffness measured during the tension responses are discussed.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents