The Journal of General Physiology
Avanti Polar Lipids, Inc.
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF, 639K)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JGP
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mlekoday, H. J.
Right arrow Articles by Levitt, D. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mlekoday, H. J.
Right arrow Articles by Levitt, D. G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

The Journal of General Physiology, Vol 81, 213-220, Copyright © 1983 by The Rockefeller University Press


ARTICLES

Osmotic water permeability of the human red cell. Dependence on direction of water flow and cell volume

HJ Mlekoday, R Moore and DG Levitt

The osmotic permeability coefficient (Pf) was measured with a stopped- flow light-scattering technique. There is an artifactual light- scattering signal produced by the initial mixing that decays with a half-time of approximately 0.2 s. This seriously interferes with the measurement of the osmotically induced change in cell volume, which has a similar half-time. This "injection artifact" is associated with the biconcave shape of the cells. It is negligible for cells that have been made nearly spherical by swelling them in 160 mosmol. The dependence of this artifact on the cell volume may explain the previously observed dependence of Pf on the cell volume. When cells are made echinocytic (and therefore spherically symmetric), this injection artifact becomes negligible at all cell volumes and Pf can be accurately measured. The Pf of echinocytic cells was nearly constant, varying by less than 10% with the direction of flow and the medium osmolarity (160-360 mosmol). The average value of Pf was 2.0 X 10(-2) cm/s (T = 23 degrees C).
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J. Biol. Chem.Home page
B. Yang and A. S. Verkman
Urea Transporter UT3 Functions as an Efficient Water Channel. DIRECT EVIDENCE FOR A COMMON WATER/UREA PATHWAY
J. Biol. Chem., April 17, 1998; 273(16): 9369 - 9372.
[Abstract] [Full Text] [PDF]



  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents