|
||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Original Article |
erios{at}rush.edu
| ABSTRACT |
|---|
|
|
|---|
Key Words: sarcoplasmic reticulum excitation–contraction coupling confocal microscopy computer algorithm
| Introduction |
|---|
|
|
|---|
By this combination of forward (i.e., simulation of sparks) and backward calculations (the release algorithm), we found that the method recovers adequately the current of release flux. We also uncovered limitations of the method, manifested in errors in the determination of release magnitude, source diameter, or release flux duration, and established circumstances that make these errors greater or reduce them.
When the release calculation algorithm was applied to sparks obtained experimentally in skeletal muscle under different conditions, the resulting flux was large by comparison with Ca2+ flux measured through single channels in bilayers under what are thought to be near-physiological conditions (Mejía-Alvarez et al. 1998
), suggesting a multichannel origin for sparks.
| Methods |
|---|
|
|
|---|
.
The fluorescence averaged in this way is represented versus r and z in Fig. 1 A. The dependence could be fitted as the product of two gaussians: P
. The two-gaussian description, which is used later in the analysis, is documented in B and C. Fig. 1 B contains data as a function of the axial coordinate z. The fluorescence values represented are averages within each section, over a 0.1425-µm circle centered on the
line (), or in a ring region 0.285 < r < 0.4275 µm (
). The lines are best fit gaussians with
, respectively, indicating some deviation from the product of gaussians at high values of r. In Fig. 1 C, the fluorescence is represented as a function of distance r at constant z. The three sets of data are from the central section (|z| < 0.18 µm; ), an intermediate region (0.18 < |z| < 0.54 µm; dotted symbols), and an outlying region (0.72 < |z| < 0.98 µm;
). The best fit gaussians shown have very similar spread
. In the analysis of data, we neglect the deviations and approximate the PSF as a product of a gaussian function of r, with
(corresponding to a full width at half magnitude [FWHM] of 0.47 µm) and a gaussian function of z, with
(FWHM of 1.44 µm). Similar values were obtained with a second C-apochromat 1.2 N.A. objective in our microscope, and with either objective in a LSM 410 (Carl Zeiss, Inc.) confocal scanner.
|
2.5x greater fluorescence intensity at comparable magnification, this fluorescence intensity is nearly independent of vertical position of the focal plane within the fluorescent object or solution, and its working distance is substantially greater. For these reasons, it was used in most of the experiments reported here.
Imaging of Fluorescence Sparks
Imaging of fluorescence sparks was carried out in segments of singly dissected semitendinosus muscle fibers of Rana pipiens (which were anesthetized in a 15% ethanol solution, and then killed by pithing), using two conventional techniques for eliciting sparks. In one, fiber segments were voltage clamped in a two-vaseline gap chamber, while their cytoplasmic medium was equilibrated with an "internal" solution containing (mM): 125 Cs-glutamate, 10 Cs-HEPES, 0.5 MgCl2, 1 EGTA, nominal [Ca2+] set to 100 nM, 0.1 fluo-3, 5 creatine-phosphate, 5 Mg-ATP, 5 glucose, pH 7.0. The "external" solution in the middle pool of the chamber contained (mM): 131.5 tetraethylammonium (TEA)–methanesulfonate, 10 TEA-HEPES, 10 Ca-methanesulfonate, 10–6 g/liter tetrodotoxin. In this case, sparks were elicited by voltage clamp depolarization to low voltages (between –70 and –50 mV). In the other technique, similar to that described by Lacampagne et al. 1998
, the fiber segment was mechanically fixed to the coverslip bottom of a single compartment chamber. Its membrane was permeabilized by several large cuts, at distances of 100–150 µm, or by brief exposure to an internal solution with 0.01% saponin, and immersed in internal solution with fluo-3. Because one of the purposes of using the permeabilized fiber was to reach higher dye concentrations more rapidly inside the cells, the internal solution in this case contained 0.2 mM fluo-3. To elicit sparks, the internal solution contained lower nominal [Mg2+] (0.15–0.3 mM; Lacampagne et al. 1998
), and total ATP was increased for a nominal [Mg ATP] of 5 mM. All solutions were titrated to pH 7.0. The experiments were carried out at 17°C.
Ca2+ sparks were imaged in line scan mode. Images are formed by juxtaposition of 768 line scans of 512 pixels obtained at 2-ms intervals and stored as arrays F(xj,ti), [sometimes referred to as F(x,t)], where j and i are integers varying between 1 and 768 and 1 and 512, respectively. Experimental images are presented normalized to the resting fluorescence F0(x), calculated by averaging F(x,t) over time. In the voltage-clamp experiments, this averaging is restricted to the interval before the depolarizing pulse. In the experiments with permeabilized fibers, it is done after removing the spark regions located automatically by a simple amplitude criterion applied to a filtered version of the image (Cheng et al. 1998
).
Analysis of Fluorescence Images
Once the events were located, all subsequent analysis was carried out on subsets of the line scan, 45 x 45 arrays, centered at the peak of the located spark. Four morphological parameters were determined first: amplitude (a) full width at half magnitude, full duration at half magnitude (FDHM), and rise time. a was determined as the difference between the peak value of the normalized fluorescence and its baseline value at the same spatial position immediately before the event (the average of 10 values between 40 and 20 ms before the peak). FWHM was determined on the spatial distribution of fluorescence at the time of maximum change. FDHM was determined on the time dependence at the spark center. Rise time as the interval between time to 10% increase from pre-event baseline and time to peak, determined on a spline interpolate of the time-dependent fluorescence, averaged over three spatial pixels at the center of the spark. Even though the event locator uses filtration steps, the morphometric measurements were carried out on the unfiltered image, normalized as described. In some cases, averages were made of the events located automatically.
Fluorescence line scan images were analyzed to derive [Ca2+](x,t) and release flux, following a procedure modified from that of Blatter et al. 1997
. When the dye concentration is low, so that autofiltration can be neglected, and the dye is in equilibrium with Ca2+, fluorescence is
![]() | (1) |
). The parameters of fluo-3 were given values within the range estimated by Harkins et al. 1993
.
DyeT, a function of position x along the scanned line, was calculated replacing F in
by F0(x), the fluorescence averaged over time during the periods of rest before the sparks of interest (or voltage pulse), and assuming the resting concentration [Ca2+]0 to be equal to the concentration in the internal solution, 100 nM.
When [Ca2+]0 is much lower than K'd (for instance at 100 nM), a simplification applies
![]() | (2) |
. For the calibration situation
, where F100 is the fluorescence in cuvette at 100 µM [Ca2+] and 100 µM dyeT. Kd is 0.48 µM in our cuvette calibrations. Assuming that the resting [Ca2+] is equal to 100 nM and that Bmax/B'max
1 (Harkins et al. 1993
2 x 100 µM (F0/F100). Because F0 is in general a function of x, dyeT is also a function of x. If, instead of 1.03 µM, we used the upper estimate of Harkins et al. 1993
2.5. In this sense, we used a low estimate of dyeT.
When [Ca2+] is changing steeply in space and time, we evaluate it as that needed to produce the observed distribution of dye:Ca2+, the concentration of which is proportional to the observed changes in fluorescence. Specifically, [dye:Ca2+] was derived from the spatially resolved fluorescence F(x,t), using
. Then [Ca2+](x,t) was obtained numerically solving the diffusion–reaction equation that governs the evolution of [dye:Ca2+]:
![]() | (3) |
is the laplacian operator (
2/
x2 +
2/
y2 +
2/
z2). The line scan only provides the partial derivative in the x direction. Blatter et al. 1997
2/
x2 as an approximation to
. M. Cannell (University of Auckland, New Zealand, personal communication) suggested assuming that the fluorescence increase is spherically symmetric, a function of time and the distance (
) to its center. In that case, the dependence of F with x gives all the information needed to calculate the laplacian correctly, as
2/
x2 + 2 (
/
x)/x. This approximation does not work when the sources of release are spatially complex (as in Blatter et al. 1997
. In actual work, this is avoided by using interpolated arrays that do not include
. Still, at the smallest x values, the operation increases local noise greatly, which may result in the appearance of spurious sources when working on noisy data. Additionally, the source may not be spheric if it is constituted by multiple channels. An estimation of the errors expected if the source was not spheric is presented in RESULTS.
Calculation of Release Flux
Calculation of release flux was done as described by Blatter et al. 1997
. The flux density of the source, represented as
, satisfies the equation
![]() | (4) |
rem/
t is a sum of terms of the form
![]() | (5) |
The terms of
are calculated from the function [Ca2+] (x,t), solving for [b:Ca2+] the diffusion–reaction equation of form 3 for the corresponding buffer. In general, this requires simultaneously solving an equation for the free buffer (see for instance ![]()
![]()
![]()
in Ríos and Stern 1997
). This is avoided in the present calculations assuming that the free buffer and its Ca2+ complex have the same diffusion coefficient, or equivalently that total buffer concentration is constant everywhere. In the case of parvalbumin and ATP, buffers that react with both Ca2+ and Mg2+, diffusion–reaction equations of form 3 still apply, but [b:Ca2+] is in both cases equal to [b]T – [b] – [b:Mg2+] (where [b]T is the total concentration of buffer), and [b:Mg2+], a function of space and time, is calculated from its own diffusion reaction equation
![]() | (6) |
Parameter values are given in Table . The SR pump contribution to removal was proportional to the fractional occupancy of pump sites of dissociation constant 1 µM, with maximum (saturation) pump rate given in the table. An exploration of the effects of changing the assumed values of the parameters is presented later.
|
Simulations (Calculations of Fluorescence Sparks)
Reaction–diffusion equations (Ríos and Stern 1997
) were written to describe the movements of Ca2+, Ca2+ -bound, and Ca2+-free fluo-3 in the presence of an isotropic myoplasm containing endogenous buffers (troponin, SR pump, parvalbumin, ATP) and EGTA. EGTA, ATP, and parvalbumin species were treated as diffusible. In most of the simulations illustrated, the spark was modeled as the fluorescence increase resulting from a 5-ms square wave release of calcium (of current intensity that varied between 0.1 and 25 pA) deposited uniformly into a sphere (the diameter of which varied between 100 and 1,500 nm). Additional simulations were carried out with other time dependencies or with cylindric sources. The reaction–diffusion equations were solved by the Galerkin finite element method with adaptive gridding, using the program PDEASE (Macsyma Inc.). The resulting function of spatial position is spherically symmetric (a function, f(
), of radial distance to the center of the release sphere), and was generated as a two-dimensional array for suitable values of
and time. To make it comparable with the experimental results, these arrays were spaced at increments of 0.15 µm and 2 ms.
The simulation approach, including the assumption of a homogeneous medium, isotropic for removal and diffusion, was similar to that of Smith et al. 1998
, who did it for a specifically cardiac removal system. The resulting sparks were of smaller normalized amplitude for the same release current in the present work, because we assumed a briefer release in a medium that included higher [fluo-3], diffusible buffers (EGTA, ATP, and parvalbumin) and a higher concentration of troponin. Additionally, we used a broader PSF when blurring the simulated sparks.
Blurring and Deblurring
Blurring, the effect of the limited resolution of the microscope when imaging fluorescence sparks, was simulated assuming a point spread function similar to that determined experimentally. Let F represent the detected fluorescence, or fluorescence in image space. The object fluorescence, f(x,y,z), is always assumed to be a spherically symmetric function (of radial distance to the center of the spark). In general (Agard et al. 1989
), the image of this object will be the convolution of f with the PSF P, which for a given time results in a function of three space coordinates.
![]() | (7) |
Because in all cases we processed or simulated line scans, we only concerned ourselves with the dependence of F on X. Additionally, we only processed sparks assumed to be centered on the scanning line. Therefore, the function F above only had to be evaluated at
. Representing F(X,0,0) as F(X),
simplifies to
![]() | (8) |
We further simplified
because the PSF, as shown in RESULTS, is approximately separable as the product of two gaussian functions:
, a function of the radial distance to the center of the scanned spot in the focal plane, and
, a function of the axial distance to the focal plane, in the z axis direction. The simulated fluorescence spark is spherically symmetrical [f
(
)]. It is well fitted by a gaussian function of polar radius (as shown with an example in DISCUSSION), namely
![]() | (9) |
With these approximations, the blurred function F(X),
, simplifies to:
![]() | (10) |
G(x – X, 0) and G(y)
G(0, y). This is done for every point in time and presented to the release calculation algorithm as a line scan image of a spark. A simulated spark before and after blurring is illustrated (see Fig. 2A and Fig. B).
|
(0) g(x)g(y)g(z). The form of the function g is deduced deriving from
![]() | (11) |
. Evaluating
, it follows that
. In more intuitive terms, deblurring changes the spatial shape of the spark from F to g, making it sharper, and rescales it by the factor 1/J 2L, which "undoes" the three-dimensional averaging and consequent loss in amplitude, due to the spread of the microscope. J and L quantify these averaging effects and are therefore smaller than 1. The final expression of the deblurred line scan is F(0)g(x)/J 2L, a function that is calculated at every time t j in the experimental arrays, or at arbitrary increments in simulations. The deblurring operation is tested in Fig. 2A and Fig. B. The simulated spark before blurring is within 5% of that recovered after successive blurring and deblurring. When applied to noisy data, deblurring may lead to uninterpretably noisy results. In such cases, we used either no or partial deblurring (assuming a sharper PSF). The effects of partial deblurring, evaluated for simulated and experimental data, are illustrated (see Fig. 4).
|
| Results |
|---|
|
|
|---|
Tests of the Algorithm on Simulated Sparks
Sparks were simulated as described in METHODS, as the increase in fluorescence determined by release of Ca2+ from a spherical source into a homogeneous medium whose removal properties copied those of the skeletal myoplasm. It includes components with the properties of the most important removal processes in the cell; namely, parvalbumin, troponin, the SR pump, the extrinsic buffer EGTA, which in the experiments analyzed later is present at 1 mM, and ATP, a rapidly diffusing low affinity buffer (Baylor and Hollingworth 1998
). The model parameters had values taken from the literature, listed in Table . Shown are simulations with a release current of 20 pA and 5-ms duration, originating from a sphere of 0.2-µm radius. These simulated sparks were similar to an average experimental spark shown later. To reproduce the conditions of this average, they were generated assuming a dye concentration of 50 µM.
Simulated sparks were first blurred (according to
) with half widths
, to produce the effect of detection by the confocal microscope in its usual configuration. The final result of the simulation, with or without blurring, is represented in Fig. 2A and Fig. B, as normalized fluorescence profiles that pass through the maximum, at constant t and x. In thin lines is the spark before blurring ("simulated"). In thick trace is the spark after imaging ("blurred"). It is broader and of approximately half the amplitude of the object spark. The release calculation algorithm starts with a deblurring step (
), which seeks to reconstruct the object spark. Its result is represented by the dashed curves ("deblurred"), and is similar to the original simulated spark.
In Fig. 2C and Fig. D, the release flux density used in the simulations is compared with that reported by the release algorithm. The release flux density used in the simulations was calculated as I/(2F)/vs (where F is the Faraday constant and vs is the volume of the source, a sphere of radius 0.2 µm) and is represented by the thin trace. The curves in the thick trace represent release flux density calculated by the algorithm ("derived"), in Fig. 2 C as a function of position (x) at the maximum of release, and in D as a function of time at the center of the source.
As seen in both representations, the derived release is a reduced and spread out version of the release used in the simulation. The peak of the derived flux is 1,750 mM/s rather than the theoretical 3,100 mM/s. The full duration at half magnitude, 4.7 ms, is in excellent agreement with release duration. The half width of the derived release is somewhat greater (0.46 µm) than that used in the simulation (0.4 µm). Total release flux was computed by volume integration of the spherically symmetric flux density. Expressed as a current (plotted versus time in Fig. 2 E) and compared with the current of 20 pA used in the simulation. The current initially lags behind the correct value and later overshoots it, but yields a reasonable estimate. This is shown in Fig. 2 F, where the peak of the derived release current is plotted against the simulation current. A good correspondence is found in the range explored, with some evidence of saturation at the high end.
Fig. 2 C illustrates that release typically undershoots, going negative at the edges of the releasing volume. This error is due in part to the use of a wide kernel for spatial differentiation. It is also due to the inherent imprecision of an analysis that samples a continuous physical phenomenon at spatial and temporal frequencies that are comparable with those in the sampled object. Though small in amplitude relative to the positive peak of release, the error becomes proportionally greater when total flux is calculated by integration over the volume of the spark. For this reason, when calculating total flux, the volume integration is stopped at the first negative value of the computed release waveform.
The method was also tested with simulations that specifically violated the assumption of spherical symmetry at the source, in which release originated from a cylinder of 1-µm length and 0.2-µm radius (not shown). The current derived by the algorithm in this case overestimated the simulation current when the simulated spark was scanned along the axis of the cylinder and underestimated it when scanning transversely. The errors, however, were within 50% in either direction.
The conclusion from this section is that the release calculation algorithm is self-consistent—it recovers approximately the input current used in simulations. More realistic tests required adding noise to the simulated sparks.
Performance of the algorithm in the presence of noise
Fig. 3 and Fig. 4 illustrate performance of the algorithm in the presence of noise. In Fig. 3, the algorithm operates on (A) the simulated fluorescence spark of Fig. 2 (corresponding to a release current of 20 pA and 5 ms), to which pseudo-random noise has been added, with normal distribution of standard deviation 3 in fluorescence units. Such noise amounts to
10% of F0, which is comparable with that of averaged experimental records. The main problem resulting from the presence of noise at this level is that the deblurring correction, which increases the higher frequency components more, may give uninterpretably noisy results. In the example, we used a partial deblurring correction for a less severe microscope spread
. The consequences of partial deblurring are explored later.
|
Because it was not possible in general to use the full deblurring correction with experimental records, we evaluated in detail the effect of deblurring under different assumptions for the system's PSF. Results are represented in Fig. 4 A, where the peak release current derived for simulations analogous to those in Fig. 2 and Fig. 3 is plotted against "deblurring length," the FWHMz assumed for correction. The values of deblurring length spanned the range from 0 (i.e., no correction), to 1.4 µm ("full correction"). In every case, FWHMxy was equal to FWHz/3.5. (Fig. 4) represents simulations without noise and
records with noise (at levels comparable with those in Fig. 3 and an average spark presented later).
It can be seen that increasing the blurring correction increases the estimate of release current, which tends to the correct values as the deblurring length increases. The changes are moderate and vary continuously with deblurring length. When noise is present, the dependence of the parameters on deblurring length changes abruptly at or near 1 µm, indicating that the deblurring correction does not work properly beyond this point (another evidence, not shown, is that the results become variable with each different realization of pseudo-random noise). This test indicates that the algorithm applied with partial deblurring still evaluates source current acceptably, to some extent underestimating it. This issue will be considered further when processing experimental sparks.
Additional tests evaluated the ability of the algorithm to monitor current when spatial aspects of the source were varied. Simulations were similar to those shown before (20 pA, 5 ms, noise at 10% of baseline fluorescence, deblurring at 0.88 µm), but the source diameter varied between 0.2 and 1.5 µm. in Fig. 4B and Fig. C, plots peak current and FWHM of the derived release against source diameter. It can be seen that the method evaluates current well at every diameter, but only follows the changes in diameter at values beyond 0.5 µm (C). The spatial dimension of the source is overestimated at diameters below 0.6 µm, an evidence of limited spatial resolution, due to noise and the optical spread of the microscope.
, in Fig. 4B and Fig. C, illustrates results of applying the algorithm to simulations with noise at 30% of F0, a level characteristic of individual experimental sparks. Under these conditions, the algorithm can be used provided that fluorescence images are smoothed first, that a more heavily filtering differentiator is used (see METHODS), and that no deblurring correction is applied. Given the high level of noise, the results change with different noise realizations. Fig. 4,
, represents averages of six realizations, bars are ±SEM. In this form, which can be applied to individual experimental sparks, the algorithm still evaluates release current within 50% error (B), but fails to report changes in source diameter under 1 µm (C). In summary, the algorithm evaluates release current well under realistic conditions of noise, within a wide range of source parameters. It is able to detect changes in source diameter above 0.7 or 0.8 µm when used with averages, or above 1 µm when used with individual sparks.
The Release Current of Experimental Sparks
The characteristics of sparks obtained with two different experimental techniques were somewhat different.
Cells under voltage clamp.
Fig. 5 A contains a line scan image obtained from a fiber under voltage clamp, which had been exposed for 45 min to an internal solution with a nominal free [Ca2+] of 100 nM and 610 µM [Mg2+]. In all experiments prepared this way, almost no sparks were observed at rest, but small pulse depolarizations elicited many, as illustrated. The plot at bottom represents the relative fluorescence averaged in a 0.43-µm wide region at the position marked by the line a–a' in Fig. 5 A. The large spark there peaked at 6.0x the resting fluorescence
. Under voltage clamp, repeated depolarizations can be applied and large numbers of sparks collected in a short period of time within a small region of the fiber. We illustrate below the application of the release algorithm to an average of such sparks.
|
in the scatter plots.
The graphs demonstrate several aspects of spark morphology that were similar in five experiments studied in the same detail (listed in Table ). Events span a wide range of amplitudes, between seven and the limit of detection. There does not seem to be any discrete segregation in morphology among sparks; that is, no systematic difference appears between the morphological parameters of large versus small amplitude sparks. Accordingly, the correlation between amplitude and the other variables is weak or nonexistent. The lines represent first order regressions to the open symbols. The regression coefficient r2 was 0.102 for the spark width (range 0.012–0.127 in six experiments) and 0.008 (0.000–0.017) for the rise time. This low correlation suggests that the observed spread in amplitude was not a consequence of the existence of multiple spatially resolved sources, which could collectively generate a large spark (such as those described in cardiac muscle by Parker et al. 1996
, or Blatter et al. 1997
), nor was it the trivial result of exceptionally long rise times in the largest sparks.
|
The application of the release algorithm to the average spark is illustrated in Fig. 6. Parameter values are listed in Table ; [Mg2+] and [Ca2+] were assumed to have the nominal internal solution values. The dye concentration was set at the average of the estimates for each event (which ranged between 38 and 42 µM). The average was centered at the peaks of the sparks and is shown in Fig. 6 A. Because of the low level of noise in the average, no smoothing or other filtering was applied. Partial deblurring was used with deblurring length = 0.88 µm; results with other degrees of deblurring are represented in Fig. 4 A,
. The release flux density calculated by the algorithm is represented in Fig. 6B–E. The derived release current is plotted in F.
|
35% (Fig. 6 F). The dependence is explicable because [fluo-3] is derived from resting fluorescence, which is approximately proportional to both [fluo-3] and [Ca2+]0, hence a change in assumed [Ca2+]0 alters [fluo-3] and the derivation of [Ca2+](x,t). In every fiber prepared the same way, several hundred sparks were identified (100 or more of which were >2.0 in amplitude). The average morphological parameters, listed in Table , and the calculated dyeT, were very similar in all cases, hence the release must have been similar.
Permeabilized fibers.
It was possible to reduce the uncertainty in the derivations by using the permeabilized fiber preparation, described in METHODS, in which the fiber membrane is cut at multiple locations and the cell is immersed in the internal solution. Intracellular fluorescence increases with a time constant of 10–20 min. For analysis of these experiments, it is assumed that free [Ca2+] has the value present in the internal solution (an assumption consistent with model simulations of Uttenweiler et al. 1998
). dyeT is derived from the internal resting fluorescence as described in METHODS. Sparks occur spontaneously in this preparation, and their frequency can be controlled by varying free [Mg2+] (Lacampagne et al. 1998
). A line scan image of a permeabilized fiber is in Fig. 7. Shown is the fluorescence normalized to its resting value F0 (x). This image is representative of several experiments in which dyeT reached a value close to 400 µM (that is, F0 reached a value close to that in the 200 µM dye internal solution in which the fiber was immersed).
|
), and their large width, close to 2 µm for all but the smallest event. These seven sparks, unusual for originating at the same spot, are not unlike other large sparks observed in permeabilized fibers. Compared with the events under voltage clamp (whose average parameter values are in Table ), large sparks in permeabilized fibers were often wider, briefer, and of shorter rise times. A detailed comparison of events under different conditions is currently in progress (G. Pizarro, A. González, W.G. Kirsch, N. Shirokova, and E. Ríos, manuscript in preparation). Fig. 8 illustrates the application of the release algorithm to an average of the four largest sparks in Fig. 7. No deblurring was used. The parameter values were the same as in the previous case, except for [Mg2+], which was set to the concentration applied, 0.15 mM. Fig. 8 A represents the spark average, after smoothing, and B–E represent the calculated release flux density. The current (F) peaked at 15.8. Half width of the release source was 1.1 µm and half duration was 7.3 ms.
|
|
As a way to gauge the likely range of the first class of errors, we imposed parameter changes in the calculation of release for the average of 157 sparks studied in Fig. 6. The changes and the resulting morphological measures of derived release current are listed in Table . Changes in parameters were introduced one at a time. For those parameters expected to have a major effect, two alternative values were used, defining a reasonable range that should comprise the actual fiber values. This was done for the diffusion coefficients of Ca2+, the dye, and ATP, and for the concentrations of ATP, EGTA, and Mg2+. For maximum pump rate and the concentrations of troponin and parvalbumin sites, only one change was explored, sufficient to demonstrate a relative lack of consequences.
|
50% (because the change increased the estimated Ca2+ concentration transient). Similar changes in current were produced by increasing threefold the dye diffusion coefficient. Because the model considers multiple removal processes, even drastically changing one removal parameter alone had little effect. The only substantial change in the estimate of current (increase by
50%), occurred when the concentration of EGTA was increased fivefold. The spatial and temporal characteristics of the derived release source were even more robust. Other than changing the properties of the dye, the only changes with major consequences on the derived release width and duration were large changes in [ATP] and the reduction of [Mg2+] to 0.15 µM (which increases the free concentrations of ATP and parvalbumin). Changes in troponin and the SR pump had little effect on the release estimate. To elicit a "low estimate" of release current, the method was applied with all buffer concentrations reduced threefold. The derived release parameters are in the last row of Table . With such low values, the release current was 8.05 pA.
A minimum estimate of another sort was reached by simply integrating the dye-binding term (
[dye:Ca2+]/
t) in the representation of flux density given by
. The meaning of this estimate is illustrated in Fig. 9, where it is developed for both the average of four sparks in Fig. 8 and a simulated spark copying the experimental conditions. Fig. 9, top, shows the concentration of dye:Ca2+, which for the experimental spark is calculated from the fluorescence following
. Fig. 9, middle, shows the rate of change of [dye:Ca2+], which in both cases reaches a pronounced maximum right before the peak of fluorescence. The bottom graphs plot this rate of change (
[dye:Ca2+]/
t) at the time of its maximum, versus x. Intuitively, the Ca2+ release flux at this time should be greater than the total flux of Ca2+ binding to the dye, which can be calculated by volume integration of the rate of change shown. The result of the volume integration, expressed as a current intensity, is plotted in the bottom graphs as a function of position, starting from zero at the center of the spark. The limiting value, reached far from the spark center, is
15 pA (0.074 fmol/s) in the experimental case. The simulated spark reaches a similar maximum rate of change, but has lesser spatial spread. Accordingly, the total flux binding to the dye in the simulation corresponds to <4 pA. In every case tested, the integrated rate at early times during a spark was less than the maximum release flux, in agreement with the idea that the other removal and diffusion processes are largely positive at these early times. The value of this dye-related estimate is listed for all events analyzed in permeabilized fibers, in the last column of Table . Its average is 8.26 pA.
|
| Discussion |
|---|
|
|
|---|
, a function of space and time), which can then be integrated to obtain total flux (or current).
Evaluation of the Algorithm
We first tested the consistency of the algorithm (or "backward" calculation) on sparks simulated as the result of Ca2+ diffusion from a finite source (the "forward" calculation). The backward calculation retrieved approximately the same total current used in the forward construction, over a wide range of release current. There were some deviations, namely the flux density in the backward calculation was
55–60% of that in the simulation, and the half width of the region where the back-calculated source resided was slightly greater than the simulation source. These errors appear to be due to the finite spatial and temporal resolution of the experimental methods, which requires discrete and necessarily coarse approximations to steeply space- and time-dependent variables. They approximately compensated each other, however, resulting in a nearly correct determination of total current.
A set of more realistic tests, which characterized the performance and limitations of the method when applied to experimental data, included noise in the records. Because Ca2+ removal and the monitoring dye reaction are mass action-driven processes that occur at finite rates, the release algorithm involves differentiation stages that increase noise. Additionally, it starts with a deblurring step, to undo the blurring introduced by imaging. Deblurring is basically a deconvolution resulting in a greater enhancement of the high (spatial) frequency components of the signal, and a disproportionate increase in noise when applied to real data.
To counter these problems, we altered the method in two ways, we used less than full deblurring (that is, deblurring for a sharper PSF than actually measured) and we used smoothing and filtering digital differentiation. The effects of changing the deblurring length (FWHM of the PSF assumed in the correction) was explored on simulated sparks. This study, illustrated in Fig. 4, shows that increasing the deblurring length gradually increases the estimate of release current. The change is gradual, albeit sizable (in going from no deblurring to full deblurring the current estimate may increase by as much as 40%). In the same tests, noise, added to the simulations at the levels found in spark averages, results in an erratic morphology of derived release beyond a certain point. This translates to a limiting value of
0.9 µm for the deblurring length.
Using this practical level of deblurring correction, we then asked how would the algorithm depend on the spatial aspects of the source, namely the diameter (because the source is assumed to be spheric). As shown in Fig. 4, the algorithm underestimated source current by
30%, regardless of source diameter. The source radius reported by the algorithm was rather insensitive to changes in actual source geometry below 0.7 µm. This limits the ability of the technique to distinguish between extended and point sources.
In summary, the algorithm slightly underestimates source current, slightly overestimates source duration, and reflects source diameter beyond
0.7 µm. Its performance is degraded when used with digital low-pass filtering, but release current is never overestimated.
Applications to Experimental Sparks
The method was applied to an average including every spark of amplitude above 2 F0 obtained under voltage clamp in the same cell. Because the images were acquired over a short period, the dye concentration varied <10%, which makes it legitimate to average the events and then process the average. There was a poor correlation between amplitude and rise time for these sparks, as well as a low positive correlation between amplitude and half width. This suggests that the selected sparks were not "special", other than by surpassing the amplitude criterion. Their large amplitude indicates that the sparks originated near the scanning line, were large as objects (i.e., before imaging), or both.
The derived source current is represented in Fig. 4 (
) for various values of deblurring length. Comparing with the values obtained with simulations, it appears that the average spark originated from a source of at least 20 pA (the release current in the simulation). The range of source widths derived for the average spark, 0.47–0.7 µm, does not allow one to tell whether the flux originated at a point or an extended source.
The algorithm was also applied to sparks from permeabilized fibers immersed in internal solution. This technique had two advantages. Dye concentrations in the few hundred micromolar were achieved rapidly inside the cells, leading to a more robust determination of release flux. An even more important advantage of the permeabilized preparation was the better determination of resting [Ca2+], which should have been close to that in the equilibrating internal solution. The method was applied to individual events or to averages of just a few, which typically required low-pass filtering of the images and did not allow for deblurring.
For 19 large sparks from 11 permeabilized cells, the average release current was 14.4 pA, and half width 0.89 µm. Considering the conditions under which the algorithm was applied, the release current is probably an underestimate, and therefore not inconsistent with the estimate of 20 pA obtained under voltage clamp.
The large source width derived under these conditions should not be overinterpreted because the algorithm applied to simulations with high noise levels was quite insensitive to source width in the range below 1 µm. Nevertheless, it is interesting that in several experiments source diameters >1 µm were derived. In all those cases, fluorescence sparks had large width. One way in which sparks of such width could be simulated in forward calculations was by assuming source diameters >1 µm. These observations therefore raise the possibility that some wide sparks of high amplitude may originate from sources of resolvable size. One problem with this interpretation is that scanning was perpendicular to the Z disks (and the long axis of the transverse tubules), hence it is difficult to imagine a structural substrate for such extended release sources. The large width of some sparks therefore remains without a convincing explanation or simulation.
Estimates of Release Current and Their Implications
The present estimates of release current underlying a spark should be compared with single channel currents recorded in bilayers, in conditions as close as possible to physiological. Mejía-Alvarez et al. (1988) studied heavy SR cardiac release channels carrying Ca2+ current in the lumenal-to-cytoplasmic direction, driven by gradients of 2–10 mM, and in the presence of high concentrations of Cs+ (as a substitute for the inhibitory effects of K+ on Ca2+ current). At 2 mM lumenal Ca2+ (similar to [Ca2+]SR values determined in cardiac muscle by Chen et al. 1996
), and in the presence of symmetric 150 mM Cs+, the single channel current was 0.35 pA. This is not the best possible representation of the physiological situation because Mg2+ was not included. It is, however, a good representation of our permeabilized fibers, in which [Mg2+] was 0.15 mM.
The comparison implies that
60 fully open channels are necessary to account for release in the sparks studied here. This number, however, is subject to multiple possible errors in parameter values or in the structure of the model itself. For this reason, we provide two lower estimates of current. One is 8.09 pA, obtained when concentrations of all the removal molecules of the muscle cell model were reduced to one third their consensus values. Another low estimate, not requiring any assumptions about removal processes, was obtained by computing the rate of change of dye-bound Ca2+ before the fluorescence peak. This estimate is equivalent to the rate of change of "signal mass," defined by Sun et al. 1998
to evaluate Ca2+ release underlying InsP3-triggered signals in Xenopus oocytes. Its average for the large sparks of Table is 8.28 pA. Using these low estimates, 20 or 25 channels are required to account for the release current.
The unitary current could be greater if [Ca2+]SR was higher than the 2 mM used in the bilayer experiments. The range of possible values of [Ca2+]SR is limited, however. In cardiac muscle, [Ca2+]SR has been found to vary within a narrow band (Chen et al. 1998
), about a decade lower than its thermodynamic limit of 10–20 mM. This agrees with evidence that the SR pump stops working, for kinetic rather than thermodynamic reasons, at a [Ca2+]SR of
5 mM (Inesi 1994
). Assuming 5 mM as the maximum possible concentration would increase at most by a factor of 2.5 the single channel current, resulting in a lower limit of eight for the number of channels simultaneously open during the rise time of a large spark.
Three recent reviews (Shirokova et al. 1998
; Cannell and Soeller 1999
; Schneider 1999
) consider the question of number of channels underlying a spark. Sparks were originally proposed to arise from one or a few channels in cardiac muscle (Cheng et al. 1993
), and one (Tsugorka et al. 1995
) or "one or two" (Klein et al. 1996
) in skeletal muscle. Evidence for a many-channel mechanism has increased with the observation of release in events smaller than sparks (Bhat et al. 1987
; Lipp and Niggli 1996
, Lipp and Niggli 1998
; Shirokova and Ríos 1996
, Shirokova and Ríos 1997
) and of multifocal sparks (Parker et al. 1996
; Blatter et al. 1997
). Similarly, it is believed that "calcium puffs" produced by release through InsP3 receptors are due to activation of multiple channels (Bootman et al. 1997
; Sun et al. 1998
). Part of the evidence for one- or two-channel mechanisms was the observation of multiple modes in the distribution of event amplitude (Tsugorka et al. 1995
; Klein et al. 1996
), but the existence of modes has been contested on the basis of simulations of confocal sampling (Pratusevich and Balke 1996
), and on theoretical grounds (Cheng et al. 1998
). In favor of single channel mechanisms, it has been shown that release under a spark starts and ends abruptly (Lacampagne et al. 1999
) and that Imperatoxin A, which induces prolonged openings of release channels in bilayers, causes the appearance in muscle fibers of long duration events of sizable amplitude (Shtifman et al. 1999
).
In a model of Stern et al. 1997
, closely packed arrays of release channels interact for activation and inactivation, by virtue of their sensitivity to Ca2+. These functionally interacting arrays, termed "couplons," correspond structurally to all the release channels on one side of one junctional segment of transverse tubule (Franzini-Armstrong and Jorgensen 1994
). In the simulations of Stern et al. 1997
, a couplon can activate rapidly, in full or in part, and then inactivate, to generate an event with properties similar to sparks. The above estimate of 60 channels in a large spark is in reasonable agreement with the number of channels that fit on one side of a junctional unit (the units of largest size, 0.9 µm, Protasi and Franzini Armstrong, personal communication, fit a double row of 60 channels at 30-nm spacing). The minimum estimate of eight channels per spark suggests instead partial couplon activation.
The present conclusions apply to sparks that were selected for their large amplitude. Examination of the amplitude distribution of sparks in view of the artifacts introduced by the process of line scanning (González et al. 1999
), indicates that there is a wide, perhaps severalfold range of spark currents. The conclusion that the large sparks studied here require at least eight open channels must therefore be accompanied by the realization that other, smaller sparks of the same fibers must involve fewer simultaneously open channels, perhaps leading to a reconciliation of the different views, as sparks would then be produced by the opening of variable numbers of channels.
Ca2+ Release in Sparks
Dr. Shirokova's permanent address is A.A. Bogomoletz Institute of Physiology, Bogomoletz St. 4, Kiev, Ukraine.
| ACKNOWLEDGMENTS |
|---|
This work was supported by grants from the National Institutes of Health (NIH) and the Muscular Dystrophy Association to E. Ríos, by intramural research programs of NIH to M.D. Stern, and a grant from NIH to N. Shirokova. A. González was the recipient of a Senior Fellowship from the American Heart Association of metropolitan Chicago.
Submitted: 13 October 1998
Revised: 7 May 1999
Accepted: 10 May 1999
| REFERENCES |
|---|
|
|
|---|
and Ca release from the sarcoplasmic reticulum in skeletal muscle, J. Gen. Physiol., 97, 1991, 913–947.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|